Limit of maximum speed based on outdoor temperature
In heating operation, maximum frequency is defined by outdoor temperature and fan mode.
A zone
12°C
B zone
14°C
C zone
-10°C
-12°C
Outdoor
temperature rises
Outdoor
temperature drops
Unit: rps
Model name
Outdoor
temperature
zone
Indoor unit fan mode
HIGH MED LOW QUIET
AUXG09KVLA
A zone 110 102 95 89
B zone 110 102 95 89
C zone 110 102 95 89
AUXG12KVLA
A zone 110 110 110 98
B zone 110 110 110 98
C zone 110 110 110 98
AUXG14KVLA
A zone 110 110 97 81
B zone 110 110 97 81
C zone 110 110 97 81
AUXG18KVLA
A zone 110 110 87 74
B zone 110 110 87 74
C zone 110 110 87 74
AUXG22KVLA
A zone 120 102 78 64
B zone 120 102 78 64
C zone 120 102 57 43
1-2. Heating operation - (04-4) - 1. Compressor frequency control