5. INDOOR FAN CONTROL
The airflow can be switched in 5 steps such as Auto, Quiet, Lo, Me, Hi, while the indoor fan only runs.
When fan mode is set at [Auto], it operates on [Me] fan Speed.
01-04
2. FAN OPERATION
3. COOLING OPERATION
Switch the airflow [Auto], and the indoor fan motor will run according to a room temperature,
as shown in Fig4.
On the other hand, if switched in [Hi] [Quiet], the indoor motor will run at a constant airflow of [Cool]
operation modes Quiet, Lo, Me, Hi, as shown in Table 5.
( Fig.4 : Airflow change - over ( Cooling : Auto ) )
1. Fan speed
( Table 5 : Indoor fan speed )
Operation mode Air flow mode
Speed (rpm)
Cooling/ Fan
Heating
Dry
X zone: 680
J zone: 680
Upper& Lower
air flow mode
Upper
air flow mode
Hi
Hi
Me
Me
Lo
Lo
Quiet
Quiet
S-Lo
Cool air prevention
(Upper/ Lower)
(Upper/ Lower)
(Upper/ Lower)
1350/ 1150
1240/ 1040
1040/ 880
840/ 700
660/ 560
660/ 560
660/ 560
1350/ ---
1280/ ---
1080/ ---
870/ ---
680/ ---
680/ ---
680/ ---
1300/ 1100
1190/ 1000
1000/ 850
820/ 690
660/ 560
660/ 560
1300/ ---
1230/ ---
1030/ ---
850/ ---
680/ ---
680/ ---
---- / ----
AGU9/ 12RLF
When the room
temperature rises
When the room
temperature drops
TR : Room temperature
Ts : Setting temperature
TR-Ts > 4°F
(2°C)
2°F > TR-Ts
(1°C)
4°F > TR-Ts > 2°F
(2°C) (1°C)
=
TR-Ts > 5°F
(2.5°C)
=
3°F > TR-Ts
(1.5°C)
5°F > TR-Ts > 3°F
(2.5°C) (1.5°C)
=
HIGH mode
MED mode
LOW mode
Powerful
Powerful
S-Lo
Operation mode Air flow mode
Speed (rpm)
Cooling/ Fan
Heating
Dry
X zone: 680
J zone: 680
Upper& Lower
air flow mode
Upper
air flow mode
Hi
Hi
Me
Me
Lo
Lo
Quiet
Quiet
S-Lo
Cool air prevention
(Upper/ Lower)
(Upper/ Lower)
(Upper/ Lower)
1440/ 1230
1330/ 1120
1100/ 930
860/ 730
660/ 560
660/ 560
660/ 560
1440/ ---
1370/ ---
1130/ ---
890/ ---
680/ ---
680/ ---
680/ ---
1440/ 1230
1330/ 1120
1100/ 930
890/ 750
660/ 560
660/ 560
1440/ ---
1370/ ---
1130/ ---
890/ ---
680/ ---
680/ ---
---- / ----
AGU15RLF
Powerful
Powerful
S-Lo