15. MANUAL AUTO OPERATION (Indoor unit body operation)
17. COMPRESSOR PREHEATING
01-14
16. FORCED COOLING OPERATION
Forced cooling operation is started when pressing MANUAL AUTO button for 10 seconds or more.
During the forced cooling operation, it operates regardless of room temperature sensor.
Operation LED and timer LED blink during the forced cooling operation. They blink for 1 second ON
and 1 second OFF on both operation LED and timer LED (same as test run operation).
Forced cooling operation is released after 60 minutes of starting operation.
The FORCED COOLING OPERATION will start as shown in Table15.
When the outdoor heat exchanger temperature is lower than 5°C and the all operation has been
stopped for 30 minutes, power is applied to the compressor and the compressor is heated.
(By heating the compressor, warm air is quickly discharged when operation is started.)
When operation was started and when the outdoor temperature rises to 7°C or greater,
preheating is ended.
( Fig.11 : Outdoor heat exchanger temperature )
ON
5°C
7°C
OFF
If MANUAL AUTO Button is set, the operation is controlled as shown in Table14.
If the remote control is lost or battery power dissipated, this function will work without the remote control.
OPERATION MODE Auto changeover
FAN CONT. MODE Auto
TIMER MODE Continuous (No timer setting available)
SETTING TEMP. 24°C
SETTING LOUVER Standard
SWING OFF
(Table 14)
Manual auto operation
OPERATION MODE
FAN CONT. MODE
TIMER MODE
SETTING TEMP.
SETTING LOUVER
SWING
( Table 15)
Forced cooling operation
Cooling
Hi
Horizontal
OFF
Room Temp is not controlled
-