- (01 - 27) -
FLOOR TYPE
AGU9-15RLF
FLOOR TYPE
AGU9-15RLF
4) Room temperature control for heating
Depending on the installed environment, correction of the room temperature sensor may be
required.
Select the appropriate control setting according to the installed environment.
(
... Factory setting)
Setting description Function number Setting value
Standard
31
00
Lower control 01
Slightly higher control 02
Higher control 03
5) Auto restart
Enable or disable automatic restart after a power interruption.
(
... Factory setting)
Setting description Function number Setting value
Enable
40
00
Disable 01
* Auto restart is an emergency function such as for power outage etc.
Do not attempt to use this function in normal operation.
Be sure to operate the unit by remote controller or external input device.
6) Room temperature sensor switching
(Only for wired remote controller)
When using the Wired remote controller temperature sensor, change the setting to "Both" (01).
(
... Factory setting)
Setting description Function number Setting value
Indoor unit
42
00
Both 01
00: Sensor on the indoor unit is active.
01: Sensors on both indoor unit and wired remote controller are active.
7) Remote controller custom code
(Only for wireless remote controller)
The indoor unit custom code can be changed.
Select the appropriate custom code.
(
... Factory setting)
Setting description Function number Setting value
A
44
00
B 01
C 02
D 03