- (01 - 28) -
FLOOR TYPE
AGU9-15RLF
FLOOR TYPE
AGU9-15RLF
8) External input control
"Operation/Stop" mode or "Forced stop" mode can be selected.
(
... Factory setting)
Setting description Function number Setting value
Operation/Stop mode
46
00
(Setting prohibited) 01
Forced stop mode 02
9) Indoor unit fan control for energy saving for cooling
Enable or disable the power-saving function by controlling the indoor unit fan rotation when the
outdoor unit is stopped during cooling operation.
(
... Factory setting)
Setting description Function number Setting value
Disable
49
00
Enable 01
00: When the outdoor unit is stopped, the indoor unit fan operates continuously following
the setting on the remote controller.
01: When the outdoor unit is stopped, the indoor unit fan operates intermittently at a very
low speed.