02 - 21
)
-
OUTDOOR UNIT
AOU9-15RL
OUTDOOR UNIT
AOU9-15RL
SAFETY DEVICES10.
Protection form
Model
AOU9RLFW AOU12RLFW AOU15RLS
Circuit protection
Current fuse
(IN THE INVERTER CASE)
20A/250V
5A/250V
Current fuse
(MAIN PRINTED
CIRCUIT BOARD)
ņ
15A/250V
3.15A/250V
Fan motor protection Terminal protection program
OFF: 212
+27
-18
°F (100
+15
-10
°C)
OFF: 203
+9
-18
°F (95
+5
-10
°C)
Compressor
protection
Terminal protection program
COMPRESSOR TEMP.
OFF:230°F (110°C)
ON:After 7 minutes