- (01 - 24) -
WALL MOUNTED TYPE
ASU18-24RLF
WALL MOUNTED TYPE
ASU18-24RLF
FUNCTION DETAILS
Functions Wall mounted
1) Filter sign
z
2) Cooler room temperature correction
z
3) Heater room temperature correction
z
4) Auto restart
z
5)
Indoor room temperature sensor
switching function
z
6) Remote controller signal code
z
7) External input control
z
1) Filter sign
The indoor unit has a sign to inform the user that it is time to clean the lter. Select the time
setting for the lter sign display interval in the table below according to the amount of dust or
debris in the room. If you do not wish the lter sign to be displayed, select the setting value for
"No indication".
(
... Factory setting)
Setting description Function number Setting value
Standard
11
00
Long interval 01
Short interval 02
No indication 03
The lter sign interval time is different according to Indoor unit type as follows.
Setting description Wall mounted
Standard 400 hours
Long interval 1000 hours
Short interval 200 hours
2) Cooler room temperature correction
Depending on the installed environment, the room temperature sensor may require a
correction.
The settings may be selected as shown in the table below.
(
... Factory setting)
Setting description Function number Setting value
Standard
30
00
Slightly lower control 01
Lower control 02
Warmer control 03
3) Heater room temperature correction
Depending on the installed environment, the room temperature sensor may require a
correction.
The settings may be changed as shown in the table below.
(
... Factory setting)
Setting description Function number Setting value
Standard
31
00
Lower control 01
Slightly warmer control 02
Warmer control 03