7. Additional charge calculation
7-1. Models: AOU24RGLX and AOU30RGLX
Refrigerant type R410A
Refrigerant amount
lb oz 4 lb 10 oz
g 2,100
¢ Refrigerant charge
Total pipe length
ft 66 or less 98 131 164 (Max.)
0.43 oz/ft
(40 g/m)
m 20 or less 30 40 50 (Max.)
Additional charge
oz 0 14.1 28.2 42.3
g 0 400 800 1,200
7-2. Models: AOUG36LMAS1 and AOUG48LMAS1
Refrigerant type R410A
Refrigerant amount
lb oz 9 lb 8 oz
g 4,300
¢ Refrigerant charge
Total pipe length
ft 98 or less 131 164 196 230 (Max.)
0.43 oz/ft
(40 g/m)
m 30 or less 40 50 60 70 (Max.)
Additional charge
oz 0 14.1 28.2 42.3 56.4
g 0 400 800 1,200 1,600
- 83 -
7-1. Models: AOU24RGLX and AOU30RGLX 7. Additional charge calculation
OUTDOOR UNIT
AOU24-30RGLX,
AOUG36-48LMAS1
OUTDOOR UNIT
AOU24-30RGLX,
AOUG36-48LMAS1