42 Installation and operating manual “1350-EN”
Heat pump, Split, single service
6741 S Temperature alarm initiation CC2 ---, 10… 240 min 10 min ---
6745 S DHW load alarm ---, 1… 48 h 1 h ---
6746 S Temperature alarm initiation Cold 1 ---, 10… 240 min 10 min ---
6800 S History 1 Time, Date, Error code
6802 S History 2 Time, Date, Error code
6804 S History 3 Time, Date, Error code
6806 S History 4 Time, Date, Error code
6808 S History 5 Time, Date, Error code
6810 S History 6 Time, Date, Error code
6812 S History 7 Time, Date, Error code
6814 S History 8 Time, Date, Error code
6816 S History 9 Time, Date, Error code
6818 S History 10 Time, Date, Error code
Maintenance / special regime
7070 I Interval time for maintenance HP --- , 1… 240 1 Month ---
7071 I Operating time HP since last maintenance.
Reset ? (no, yes)
0… 240 1 Month 0
7072 I Maximum number of starting of the compressor 1,
authorized per hour of operation.
--- , 0,1 12 0,1 ---
7073 I Average number of starts of the compressor per hour of
operation, since the 6 last weeks.
Reset ? (no, yes)
0…12 0
7076 I Maximum discrepancy condens / week --- , 1… 250 1 ---
7077 I Current maximum discrepancy condens / week
Reset ? (no, yes)
0… 250
7078 I Minimum discrepancy condens / week --- , 1… 250 1 ---
7079 I Current minimum discrepancy condens / week
Reset ? (no, yes)
0… 250 0
7090 I DHW tank period --- , 1… 240 1 Month ---
7091 I DHW tank since maintenance
Reset ? (no, yes)
0… 240 0
7092 I Heat pump DHW min load temperature 5… 80 °C 1 C
7141 U Emergency regime Off, ON Off
Off: The heat pump does not use the backup electrical heating system or the boiler connection when a fault occurs (error
370)
ON: The heat pump uses the backup electrical system or the boiler connection when a fault occurs (error 370).
In the "ON" position, the energy costs can be onerous if the error is not eliminated.
7142 S Emergency service operating type Manual, Automatic Manual
Manual: Emergency mode is not active when a fault occurs. (Emergency mode = OFF)
Automatic: Emergency mode is active when a fault occurs. (Emergency mode = ON)
In automatic position, the energy cost can be onerous if the error is not detected and eliminated.
7150 I Outside temperature simulation --- , -50 50 °C 0,5 ---
7181 I Contact's telephone 1 0 255
7183 I Contact's telephone 2 0 255
Line
Function Setting range
or display
Setting
increment
Basic
setting

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOY54LJBYL and is the answer not in the manual?

Fujitsu AOY54LJBYL Specifications

General IconGeneral
BrandFujitsu
ModelAOY54LJBYL
CategoryHeat Pump
LanguageEnglish

Related product manuals