EasyManuals Logo

Fujitsu AOYG09KGCA Design & Technical Manual

Fujitsu AOYG09KGCA
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
¢
External input and output PCB
A twisted pair cable should be used. Maximum length of cable is 25 m.
Output voltage: High DC 12 V±2 V, Low 0 V.
Permissible current: 50 mA
For details, refer to
"Setting of external input and output" on page 26.
When indicator or other components are connected directly:
Example: Rotary SW on External input and output PCB is set to “1”.
1
2
CN310
LED 1
(Operation status)
PCB
Resistor
Connected device
+
-
1
2
CN311
LED 2
(Error status)
Resistor
+
-
1
2
CN312
LED 3
(Indoor unit fan
operation status)
Resistor
+
-
When connecting with a device equipped with a power supply:
Example: Rotary SW on External input and output PCB is set to “1”.
1
2
Connected device 1
CN310
PCB
Connected device Relay
(Operation status)
-
+
1
2
Connected device 2
CN311
(Error status)
-
+
1
2
Connected device 3
CN312
(Indoor unit fan
operation status)
-
+
- 25 -
8-2. External output
8. External input and output
WALL MOUNTED
ASYG07-14KGT
WALL MOUNTED
ASYG07-14KGT

Table of Contents

Other manuals for Fujitsu AOYG09KGCA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOYG09KGCA and is the answer not in the manual?

Fujitsu AOYG09KGCA Specifications

General IconGeneral
TypeAir conditioner outdoor unit
Multi-split-
Product colorWhite
Inverter technologyYes
Refrigerating mediumR32
Dehumidifying capacity1.3 l/h
Air conditioner functionsCirculation, Cooling, Dehumidifying, Fan, Heating, Ventilating
Refrigerating medium weight750 g
Cooling capacity in watts (nominal)- W
Cooling energy efficiency (EER, W/W)4.5
Heating energy efficiency (COP, W/W)5
Seasonal efficiency rating (cooling) (SEER)8.52
Seasonal efficiency rating (heating) (SCOP)5.11
Current (cooling)6.5 A
Current (heating)9 A
Design load (cooling)2.5 kW
Annual energy consumption (cooling)103 kWh
Hourly energy consumption (cooling)2.5 kWh
Hourly energy consumption (heating)2.8 kWh
Design load (heating) (Warmer heating season)2.4 kW
Design load (heating) (Average heating season)- kW
Energy efficiency class (heating) (Average heating season)A+++
Annual energy consumption (heating) (Warmer heating season)658 kWh
Annual energy consumption (heating) (Average heating season)- kWh
Indoor unit noise level (high speed)- dB
Outdoor unit depth290 mm
Outdoor unit width799 mm
Outdoor unit height542 mm
Outdoor unit weight30000 g
Outdoor units quantity1
Outdoor unit noise level63 dB
Cooling airflow (outdoor unit)1610 m³/h