EasyManua.ls Logo

Fujitsu AOYG09KGCA - Page 36

Fujitsu AOYG09KGCA
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
¢
Indoor unit fan operation status
Function
setting
External input and
output PCB
External output Output signal Status
Rotary switch
60-10 C Output of indoor unit CN47
Off → On Fan run
On → Off Fan stop
2, B
External input and
output PCB
CN311
Off → On Fan run
On → Off Fan stop
1
External input and
output PCB
CN312
Off → On Fan run
On → Off Fan stop
Output signal Condition
On The indoor unit fan is operating.
Off
The fan is stopped or during cold air prevention.
During thermostat off when in dry mode operation.
Fan run
Fan stop
On
Off
CN47
On
Off
CN311, 312
Indoor unit
- 32 -
8-5. Details of control output function
8. External input and output
WALL MOUNTED
ASYG07-14KGT
WALL MOUNTED
ASYG07-14KGT

Table of Contents

Other manuals for Fujitsu AOYG09KGCA

Related product manuals