( Fig.1 : Outdoor temperature zone )
1. COOLING OPERATION
A sensor (room temperature thermistor) built in the indoor unit body will usually perceive
difference or variation between a set temperature and present room temperature, and
controls the operation frequency of the compressor.
Minimum
frequency
Maximum
frequency
Maximum
frequency
ASYG07/09LECA
ASYG12LECA
ASYG14LECA
22rps 76rps
18rps
68rps
80rps
36°C
A zone
34°C
32°C
B zone
30°C
21°C
C zone
19°C
D zone
Indoor fan mode
Me Lo Quiet
A zone 79rps 61rps 52rps 37rps
B zone 79rps 61rps 52rps 37rps
C zone 79rps 61rps 52rps 37rps
ASYG07LECA
ASYG09LECA
D zone 52rps 43rps 37rps 28rps
E zone 64rps 55rps 49rps 36rps
F zone 64rps 55rps 49rps 36rps
( Table 1 : Compressor frequency range )
01-01
E zone
F zone
10°C
0°C
12°C
2°C
* When the room temperature is between +2°C to -2.5°C of the setting temperature,
the compressor frequency is controlled within the range shown in Table1.
However, the maximum frequency is limited in the range shown in Fig.1 based on the indoor
fan mode and the outdoor temperature.
* If the room temperature is some degrees lower than a set temperature,
the compressor will be stopped.
ASYG12LECA
ASYG14LECA
A zone 96rps 61rps 51rps 33rps
B zone 96rps 61rps 51rps 33rps
C zone 96rps 61rps 51rps 33rps
D zone 57rps 42rps 36rps 27rps
E zone 57rps 42rps 36rps 27rps
F zone 57rps 42rps 36rps 27rps
Outdoor
temperature drops
Outdoor
temperature rises
( Table 2 : Limit of maximum speed based on outdoor temperature )
79rps
96rps
Outdoor
temp. zone
Hi
* If the room temperature is 2°C higher than a set temperature, the compressor operation
frequency will attain to maximum performance.
When the compressor operates for 30 minutes continuously at over the maximum frequency ,
the maximum frequency is changed from Maximum Frequency to Maximum Frequency .

Other manuals for Fujitsu AOYG09LEC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOYG09LEC and is the answer not in the manual?

Fujitsu AOYG09LEC Specifications

General IconGeneral
BrandFujitsu
ModelAOYG09LEC
CategoryAir Conditioner
LanguageEnglish

Related product manuals