3-2. Outdoor fan control
¢ Outdoor fan motor
This outdoor unit has a DC fan motor. (Control method is different between AC and DC motors.)
¢ Fan speed
Model: AOYG18KBTB
Fan speed is defined by outdoor temperature and compressor frequency.
Outside air temperature zone selection
21°C
Outside air
temperature rises
Z zone
Y zone
F zone
G zone
Outside air
temperature drops
12
°C
2°C
-8°C
19°C
10°C
0°C
-10°C
H zone
Unit: rpm
Fan step
Cooling
Heating
Dry Cooling or dry at low outdoor temp.
Y zone Y zone Z zone F zone G zone H zone
S-HIGH2 1,100
S-HIGH1 1,050 1,100
HIGH 1,050 1,100
10 1,100
9 1,050 1,100 1,050 850 320 270 270
8 1,050 750 1,050 850 320 270 270
7 870 710 870 770 320 270 270
6 870 570 870 630 270 230 230
5 770 510 770 440 270 230 200
4 630 470 630 320 270 230 200
3 510 420 510 320 270 230 200
2 400 420 400 320 270 230 200
1 400 420 400 320 270 230 200
NOTE:
After defrost control on the heating mode, the fan speed is kept higher regardless of the
compressor frequency.
Fan speed after defrost control: 1,100 rpm
3-2. Outdoor fan control
- (04-18) - 3. Fan control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Table of Contents

Other manuals for Fujitsu AOYG12KATA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOYG12KATA and is the answer not in the manual?

Fujitsu AOYG12KATA Specifications

General IconGeneral
BrandFujitsu
ModelAOYG12KATA
CategoryAir Conditioner
LanguageEnglish

Related product manuals