EasyManua.ls Logo

Fujitsu AOYG24KLTA - Specifications

Fujitsu AOYG24KLTA
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1. Specifications
Type Inverter heat pump
Model name AOYG18KLTA AOYG24KLTA
Power supply 230 V ~ 50 Hz
Available voltage range 198—264 V
Starting current A 8.0 10.9
Fan
Airflow rate
Cooling
m
3
/h
1,830 2,885
Heating 2,265 3,030
Type × Q'ty Propeller fan × 1
Motor output W 23 49
Sound pressure level *1
Cooling
dB (A)
50 55
Heating 56 57
Sound power level
Cooling
dB (A)
61 65
Heating 66 67
Heat exchanger type
Dimensions
(H × W × D)
mm
Main1: 504 × 881 × 18.19
Main2: 504 × 851 × 18.19
Main1: 588 × 881 × 18.19
Main2: 588 × 851 × 18.19
Fin pitch 1.3
Rows × Stages
Main1: 1 × 24
Main2: 1 × 24
Main1: 1 × 28
Main2: 1 × 28
Pipe type Copper
Fin type
Type (Material) Aluminum
Surface treatment PC fin
Compressor
Type × Q'ty Twin rotary × 1
Motor output W 900 1,060
Refrigerant
Type (Global warming potential) R32 (675)
Charge g 850 1,100
Refrigerant oil
Type FW68S RmM68AF
Amount
cm
3
350 400
Enclosure
Material Steel sheet
Color
Beige
Approximate color of Munsell 10YR 7.5/1.0
Dimensions
(H × W × D)
Net
mm
542 × 799 × 290 632 × 799 × 290
Gross 602 × 940 × 375 692 × 940 × 375
Weight
Net
kg
33 38
Gross 36 42
Connection pipe
Size
Liquid
mm (in)
Ø 6.35 (Ø 1/4)
Gas Ø 9.52 (Ø 3/8) Ø 12.70 (Ø 1/2)
Method Flare
Pre-charge length
m
15
Max. length 25 30
Max. height difference 20 25
Operation range
Cooling
°C
-10 to 46
Heating -15 to 24
Drain pipe
Material PP+HDPE
Size mm Ø 13.0 (I. D.), Ø 16.0 to Ø 16.8 (O. D.)
NOTES:
Specifications are based on the following conditions:
Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB
Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB
Pipe length: 5 m, Height difference: 0 m (Between outdoor unit and indoor unit)
Protective function might work when using it outside the operation range.
*1: Sound pressure level
Measured values in manufacturer’s anechoic chamber
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
DESIGN & TECHNICAL MANUAL
- 26 -
OUTDOOR UNIT