EasyManuals Logo

Fujitsu AOYG54KRTA Service Manual

Fujitsu AOYG54KRTA
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #106 background imageLoading...
Page #106 background image
Check point 6. Check strainer
Strainer normally does not have temperature difference between inlet and outlet as shown be-
low.
Pipe (In) Pipe (Out)
If there is a difference like shown below, there is a possibility of inside clogged. In this case,
replace the strainer.
Pipe (In) Pipe (Out)
4-3. Outdoor unit Electronic Expansion Valve (EEV) - (03-56) - 4. Service parts information
TROUBLESHOOTING
TROUBLESHOOTING