Water is produced from the outdoor unit
*
During heating operation, water may be produced from the
outdoor unit due to the automatic defrosting operation.
<<SEE PAGE 33>>
The lter indicator blinks
Clean the lter. Afterwards, turn the Filter indicator o󰀨.
<<SEE PAGE 24>>
thermo sensor display on the remote controller is
ashing
The room temperature sensor may be malfunctioning.
Please consult authorized service personnel.
Airow is stopped and
is displayed on the icon
display of the “Monitor” screen
Airow is stopped due to the automatic defrosting, oil
recovery, or mode mismatch.
Order of timer patterns from [Time 1] to [Time 8] in
[Weekly timer setting] is di󰀨erent from what you
registered
If more than 2 timer patterns per a day are registered in
[Weekly timer setting] and they are not in proper time
order, those patterns are sorted automatically in time
order when you nalize the [Weekly timer setting]. (Sort-
ing function)
<<SEE PAGE 13>>
Humidity does not drop
In the case of dry operation.
In some conditions of the room, the humidity does not
drop.
In order to lower the humidity, set a lower room tempera-
ture.
z
Check once more
Does not operate at all
Has the circuit breaker been turned o󰀨?
Has there been a power failure?
Has a fuse blown out, or a circuit breaker been tripped?
Is the timer operating?
Is key lock enabled?
<<SEE PAGE 26>>
Poor cooling (or heating*) performance
Is the air lter dusty?
Are the air conditioner’s intake grille or outlet port blocked?
Did you adjust the room temperature settings
(thermostat) correctly?
Is there a window or door open?
In the case of cooling operation, is a window allowing
bright sunlight to enter? (Close the curtains.)
In the case of cooling operation, are there heating
apparatus and computers inside the room, or are there
too many people in the room?
In the unit set for quiet operation?
Do you have an arrangement with your electric company
for demand response?
Following functions cannot be set:
Economy
Set temp. auto return
Set temp. range limitation
On timer
O󰀨 timer
Weekly timer
Auto-o󰀨 timer
If the function you are selecting is restricted by
[Management] function, following message is displayed
in the operation guidance display.
XXXXXX
XXXXXX
Restricted by the management function
Back:
Has the function setting been set to [Enable] or [On]?
On timer or O󰀨 timer does not work
Has there been a power outage? Any power outage
cancels the On or O󰀨 timer.
After the power supply is resumed, set the [Enable/
Disable setting] to [Enable] again.
<<SEE PAGE 12, 13>>
Weekly timer does not work
Have all the necessary settings been completed in
[Weekly timer setting]?
<<SEE PAGE 13 to 20>>
Operation is automatically stopped
Has o󰀨 timer been set?
Has weekly timer been set?
<<SEE PAGE 13>
Has auto-o󰀨 timer been set?
<<SEE PAGE 20>>
Operation does not stopped even if auto-o󰀨 timer has
been set
Has the operation been started by pressing the [On/O󰀨
button] on this remote controller?
Has the operation been started by weekly timer or on timer
?
Has the weekly timer been on during the counting down
of the Auto-o󰀨 timer?
Has it been within the valid hour?
<<SEE PAGE 20>>
Has there been a power outage? Any power outage can-
cels the Auto-o󰀨 timer.
Is message [R.C. prohibition (All, on/o󰀨)] and
icon
displayed?
<<SEE PAGE 4>>
Set temperature is changed automatically
Has set temp. auto return been set?
<<SEE PAGE 10>>
Does not return to the set temperature
Has set temp. auto return been set?
<<SEE PAGE 11>>
Set temperature cannot be changed
Has set temp. range limitation been set?
<<SEE PAGE 11>>
Is message [R.C. prohibition (Set temp. all)] and
icon
displayed?
<<SEE PAGE 4>
If the problem persists after performing these checks, or
if you notice burning smells, stop operation immediately,
disconnect the power supply, and consult with authorized
service personnel.