EasyManuals Logo

Fujitsu ARXG07KSLAP Service Instruction

Fujitsu ARXG07KSLAP
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
OUTDOOR UNIT Error Method:
Detective Actuators:
Detective details:
Forecast of Cause:
Indicate or Display:
Trip terminal L error
Outdoor unit Main PCB
1. Outdoor unit Main PCB failure
When the signal from FO terminal of IPM is "L"(=0V)
while the compressor stops.
Check Point 1 : Replace Main PCB
Replace Outdoor unit Main PCB.
Error code : 65
Outdoor unit : No indication
02-22
Trouble shooting 21

Table of Contents

Other manuals for Fujitsu ARXG07KSLAP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ARXG07KSLAP and is the answer not in the manual?

Fujitsu ARXG07KSLAP Specifications

General IconGeneral
BrandFujitsu
ModelARXG07KSLAP
CategoryAir Conditioner
LanguageEnglish

Related product manuals