EasyManuals Logo

Fujitsu ASBA24LFC User Manual

Fujitsu ASBA24LFC
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
En-9
SLEEP TIMER OPERATION
Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped.
To Use the SLEEP Timer
While the air conditioner is operating or stopped, press the
SLEEP button (Fig. 6 J).
The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) lights and the TIMER
Indicator Lamp (green) (Fig. 3 6) light.
To Change the Timer Settings
Press the SLEEP button (Fig. 6 J) once again and set the time
using the TIMER SET ( / ) buttons (Fig. 6 P).
Set the time while the Timer Mode Display is ashing (the ashing will continue about
ve seconds).
button: Press to advance the time.
button: Press to reverse the time.
About ve seconds later, the entire display will reappear.
To Cancel the Timer:
Use the TIMER MODE button to select “CAN-
CEL”.
The air conditioner will return to normal opera-
tion.
To Stop the Air Conditioner During
Timer Operation:
Press the START/STOP button.
About the SLEEP Timer
To prevent excessive warming or cooling during sleep, the SLEEP timer function automatically modi es the thermostat setting in ac-
cordance with the set time setting. When the set time has elapsed, the air conditioner completely stops.
During Cooling/Dry operation:
When the SLEEP timer is set, the thermostat setting is automati-
cally raised 1 °C every sixty minutes. When the thermostat has
been raised a total of 2 °C, the thermostat setting at that time is
maintained until the set time has elapsed, at which time the air
conditioner automatically turns off.
SLEEP timer setting
During Heating operation:
When the SLEEP timer is set, the thermostat setting is
automatically lowered 1 °C every thirty minutes. When the ther-
mostat has been lowered a total of 4 °C, the thermostat setting
at that time is maintained until the set time has elapsed, at which
time the air conditioner automatically turns off.
SLEEP timer setting
2 °C
3 °C
4 °C
30
minutes
1 °C
1 hour
1 hour
30 minutes
Set time
Set time
1 hour
1 °C
2 °C
MANUAL AUTO OPERATION
Use the MANUAL AUTO operation in the event the Remote Controller is lost or otherwise unavailable.
How To Use the Main Unit Controls
Press the MANUAL AUTO button (Fig. 2 2) on the main unit
control panel.
To stop operation, press the MANUAL AUTO button (Fig. 2 2) once again.
(Controls are located inside the Open Panel)
When the air conditioner is operated with
the controls on the Main Unit, it will oper-
ate under the same mode as the AUTO
mode selected on the Remote Controller
(see page 7).
The fan speed selected will be “AUTO”
and the thermostat setting will be stand-
ard.(24
°C)
9315345318-03_OM.indb 99315345318-03_OM.indb 9 2/26/2013 11:12:56 AM2/26/2013 11:12:56 AM