20. HUMAN SENSOR
(Table16)
Mode Cooling/Dry Heating
TargettemperatureSettingtemp.+2℃Settingtemp.-4℃
21. OUTDOOR UNIT LOW NOISE OPERATION
TheOutdoorunitlownoiseoperationfunctionsbypressingOUTDOORUNITLOWNOISEbutton
ontheremotecontroller.
ThisoperationstopsthePFCcontrol,andchangestheCurrentreleaseoperation/releasevalue.
Outdoorunitlownoiseoperationmodecanbeusedduringcooling,
heatingandautomaticoperation.ItcannotbeusedinFanandDrymode
TheHumansensorfunctionsbypressingSENSO R buttonontheremotecontroller.
Whenthesensordetectsthatthereisnooneintheroomfor20minutesormore,
itautomaticallychangestheoperationasbelowsettings.
Whensomeonecomesbackintotheroom,thehumansensorwilldetectthis,and
automaticallyreverttotheoriginalsettings.
Cool/Dry
Currentrelease
Operation/Releasevalue
Heat
5.0A/4.5A 5.0A/4.5AASTG18/22/24KMTC
(Table17)
90°
7m
7m
50° 50°
Verticalangle90°(Sideview) Horizontalangle100°(Topview)
(Applicationrange)
Thesensorunitshoulddetectwhenthehumanbody(estimate:100cmX30cm)ortheobject
whichhasmorethan4°Ctemp,differencefromthebackgroundandarecrossedwith
1.0m/sspeedinfrontofthesensorunit.
01-14
22. POWERFUL OPERATION
ThePowerfuloperationfunctionsbypressingPOWERFULbuttonontheremotecontroller.
Theindoorunit&outdoorunitwilloperateatmaximumpowerasshowninTable18.
ReleaseConditionisasfollows.
[Cooling/Dry]
- Roomtemperature<Settingtemperature-0.5°CorOperationtimehaspassed20minutes.
COMPRESSORFREQUENCY
FANCONT.MODE Powerful
Maximum
SETTINGLOUVER Cooling/Dry:3,Heating:6
(Table18)
Powerfuloperation
=
=
[Heating]
- Roomtemperature>Settingtemperature+0.5°CorOperationtimehaspassed20minutes.