WALL MOUNTED TYPE
ASU9-15RLS3
WALL MOUNTED TYPE
ASU9-15RLS3
10) Heat Insulation condition (building insulation)
Heat insulation conditions differ according to the installed environment.
Standard insulation "00" allows system to rapidly respond to the cooling or heating load
changes. High insulation "01" is when the heat insulation structure of the building is high and
does not require system to rapidly respond to cooling or heating load changes.
When High insulation "01" is selected;
Overheating (overcooling) is prevented at the start-up.

All room temp. control settings (Function 30, 31, 92, 93) will reset to No correction [0.0°F
(0.0°C)].
(
... Factory setting)
Function number Setting value Setting description
95
00 Standard insulation
01 High insulation
NOTE:
When changing Function 95, perform this setting before other Room temp. control settings (Function 30, 31, 92,
93). If Function 95 is not set rst, Room temperature control settings (Function 30, 31, 92, 93) will be reset and
you must re-do them again.