EasyManuals Logo

Fujitsu ASU18RLF Service Manual

Fujitsu ASU18RLF
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #23 background imageLoading...
Page #23 background image
When the power was interrupted by a power failure, etc. during operation, the operation contents
at that time are memorized and when power is recovered, operation is automatically resumed with
the memorized operation contents.
( Table 13 : Operation contents memorized when the power is interrupted )
12. AUTO RESTART
13. MANUAL AUTO OPERATION
If MANUAL / AUTO Button is pushed continuous from 3 seconds to 10 seconds,
manual auto operation will starts.
If the remote control is lost or battery power dissipated, this function will work without the remote control.
OPERATION MODE
Auto changeover
Auto
Continuous
(No timer setting available)
76°F(24°C)
( Table 14 : Manual auto operation control )
SETTING TEMP.
FAN MODE
TIMER MODE
*It is necessary to set on the DIP-SW1-No,6 of the wired remote controller, to enable the memory backup.
Refer to the installation manual of wired remote controller for details.
SWING OPERATION
ECONOMY
OFF
OFF
VERTICAL LOUVER
NORMAL
NORMAL
HORIZONTAL LOUVER
All models
Functions
: Memorize
: Not memorize
Operation mode
Set temperature
Set air flow
Thermistor detected position
Timer mode
Wireless remote controller
Wired remote controller
(When Memory Backup : Disable)
Wired remote controller
(When Memory Backup : Enable)
OFF Timer
ON Timer
WEEKLY Timer
TEMPERRATURE
SET BACK Timer
01-20

Table of Contents

Other manuals for Fujitsu ASU18RLF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASU18RLF and is the answer not in the manual?

Fujitsu ASU18RLF Specifications

General IconGeneral
BrandFujitsu
ModelASU18RLF
CategoryAir Conditioner
LanguageEnglish

Related product manuals