EasyManuals Logo

Fujitsu ASU18RLF Service Manual

Fujitsu ASU18RLF
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
OKOK
1. The selection of indoor units is incorrect 2. Main PCB(Outdoor unit) failure
Test 1 : Check the total capacity of indoor unit
Check the total capacity of the connected indoor units.
>> If abnormal condition is found, correct it by referring
to Installation Manual or Design & Technical Manual.
Test 2 : Replace Main PCB
If Test 1 do not improve the symptom, replace Main PCB of Outdoor unit.
(SERVICE PARTS INFORMATION 10)
Trouble shooting 5
INDOOR UNIT Error Method:
Indoor Unit Capacity Error
All indoor unit
The total capacity of the indoor unit if it is install beyond.
Detective Actuators:
Detective details:
Indicate of Display:
Forecast of Cause:
02-09
Indoor Unit
Outdoor Unit
Operation lamp : 2 time Flash
ERROR CODE : [E : 22]
Timer lamp: 2 time Flash
Monitor
ABCDEF
2
: Light ON : Light OFF n : n time blinking
2

Table of Contents