SPLIT TYPE
ROOM AIR CONDITIONER
Models Indoor unit Outdoor unit
AOU36RLXFZH
AOU45RLXFZ
INVERTER MULTI
SERVICE
INSTRUCTION
R410A
Compact Wall Mounted
Wall Mounted / Floor
Compact Cassette / Slim Duct
ARU7RLF
ARU9RLF
ARU12RLF
ARU18RLF
ARU24RLF
AUU7RLF
AUU9RLF
AUU12RLF
AUU18RLF
ASU18RLF
ASU7RLF1
ASU9RLF1
ASU12RLF1
AGU9RLF
AGU12RLF
AGU15RLF
ASU24RLF

Table of Contents

Other manuals for Fujitsu ASU7RLF1

Questions and Answers:

Fujitsu ASU7RLF1 Specifications

General IconGeneral
BrandFujitsu
ModelASU7RLF1
CategoryAir Conditioner
LanguageEnglish

Summary

Control Operations

1. CAPACITY CONTROL

Defines compressor frequency based on various conditions.

2. AUTO CHANGEOVER OPERATION

Automatically switches between Heating, Cooling, Dry, and Monitoring modes.

3. INDOOR FAN CONTROL

Controls indoor fan speed and airflow modes for different operations.

Fan Operation

Controls indoor fan speed and airflow modes.

Cooling Operation

Manages airflow based on room temperature during cooling.

4. DRY OPERATION (Auto : Dry)

Automatically controls indoor fan speed during dry operation.

5. HEATING OPERATION (Auto : Heating)

Manages airflow based on room temperature during heating.

6. COOL AIR PREVENTION CONTROL (For Heating and Minimum Heat operation)

Sets indoor fan speed to prevent cool air during heating.

4. LOUVER CONTROL

Manages vertical and horizontal airflow direction and swing.

1. VERTICAL LOUVER CONTROL

Controls vertical airflow direction and swing ranges.

2. SWING OPERATION

Manages louver swing for airflow direction.

Horizontal Louver Control

Controls horizontal airflow direction and swing.

Adjust Right-Left Louvers

Allows manual adjustment of right-left louvers for preferred airflow.

5. Outdoor Fan CONTROL

Controls the fan speed of the outdoor unit.

6. COMPRESSOR CONTROL

Manages compressor operation frequency and start-up control.

7. TIMER OPEARTION CONTROL

Allows setting ON/OFF, Program, and Sleep timers for operation.

8. ELECTRONIC EXPANSION VALVE CONTROL

Controls the opening of the electronic expansion valve based on operating conditions.

9. TEST OPERATION CONTROL

Procedures for performing test runs of the air conditioner system.

10. PREVENT TO RESTART FOR 3 MINUTES (3 MINUTES ST)

Prevents compressor restart for 3 minutes after stopping.

11. 4-WAY VALVE EXTENSION SELECT

Manages 4-way valve switching timing between cooling and heating.

12. AUTO RESTART

Automatically resumes operation with memorized contents after power interruption.

13. MANUAL AUTO OPERATION

Allows manual auto operation without a remote controller.

14. COMPRESSOR PREHEATING

Heats the compressor when the outdoor temperature is very low.

15. POWERFUL OPERATION (For ASU*RLF1/ AGU*RLF type)

Provides maximum power operation for indoor and outdoor units.

16. MINIMUM HEAT OPERATION

Performs minimum heat operation via MIN. HEAT button or timer setting.

17. ECONOMY OPERATION

Reduces output for cooling and heating, saving energy.

18. HEAT INSULATION CONDITION (BUILDING INSULATION)

Optimizes room temperature control for buildings with high insulation.

19. THERMO CONTROL (FOR INDOOR UNIT SENSOR)

Controls compressor operation based on indoor unit sensor readings.

20. THERMO CONTROL (FOR WIRED REMOTE SENSOR)

Controls compressor operation based on wired remote sensor readings.

21. BASE HEATER OPERATION (For AOU36RLXFZH)

Controls base heater operation based on outdoor temperature.

22. FRESH AIR CONTROL (For AU type)

Synchronizes fresh air fan operation with indoor fan.

23. EXTERNAL ELECTRICAL HEATER CONTROL (For AR type)

Controls external electrical heater operation based on specific conditions.

24. DRAIN PUMP OPERATION (For AU / AR type)

Details drain pump operation during cooling, dry, heating, and stop modes.

25. AIR OUTLET SELECTION ( DAMPER CONTROL )( For AG type)

Controls air outlet direction (upper/lower) for effective cooling/heating.

26. DEFROST OPERATION CONTROL

Manages defrost operation based on temperature sensors and operating time.

27. CHECK RUN OPERATION (AUTOMATIC WIRING CORRECTION)

Performs automatic wiring correction and checks connection status.

28. VARIOUS PROTECTIONS

Covers various protection mechanisms for system safety.

4. HIGH TEMPERATURE RELEASE CONTROL (Heating mode)

Controls compressor frequency based on discharge pressure during heating.

5. HIGH PRESSURE PROTECTION

Protects the system from high pressure during operation.

6. COMPRESSOR TEMPERATURE PROTECTION

Stops the compressor if its temperature exceeds a limit.

29. PUMP DOWN OPERATION

Procedure for pump down operation when moving or discarding the unit.

30. TEST RUN (For Outdoor unit)

Method for performing test runs on the outdoor unit.

Troubleshooting

2-1 ERROR DISPLAY

Details error codes displayed on indoor units and remote controllers.

2-1-1 INDOOR UNIT AND WIRED REMOTE CONTROLLER DISPLAY

Shows error codes via indoor unit and remote controller displays.

2-1-2 SIMPLE REMOTE CONTROLLER DISPLAY

Displays error codes on simple remote controllers.

2-1-3 CENTRAL REMOTE CONTROLLER DISPLAY

Displays error codes for multiple indoor units via central controller.

2-1-4 OUTDOOR UNIT DISPLAY

Displays error codes and locations via outdoor unit LEDs.

2-2 TROUBLE SHOOTING WITH ERROR CODE

Provides diagnostic steps for errors indicated by codes.

Serial Communication Error (Serial Reverse Transfer Error)

Troubleshoots serial communication errors between units.

2-3 TROUBLE SHOOTING WITH NO ERROR CODE

Provides diagnostic steps for issues without specific error codes.

Indoor unit - No Power

Troubleshooting steps for when the indoor unit has no power.