EasyManuals Logo

Fujitsu ASUG09LMAS User Manual

Fujitsu ASUG09LMAS
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
8-6. High temperature and high pressure release control
The compressor is controlled as follows.
¢ Models: AOUG09LMAS1 and AOUG12LMAS1
Indoor unit heat exchanger
temperature rises
Indoor unit heat exchanger
temperature drops
Stable zone
AB
BC
CD
DE
Zone A
Zone B
Zone C
Zone D
Zone E
AB: 63°C
BC: 55°C
CD: 53°C
DE: 50°C
Zone Operation
Zone A Compressor is stopped.
Zone B
The compressor frequency is decreased.
-25 rps/120 sec.
Zone C -3 rps/60 sec.
Zone D
The protection is released and the operation is returned to normal mode.
Zone E
8-6. High temperature and high pressure release control - (04-27) - 8. Various protections
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASUG09LMAS and is the answer not in the manual?

Fujitsu ASUG09LMAS Specifications

General IconGeneral
BrandFujitsu
ModelASUG09LMAS
CategoryAir Conditioner
LanguageEnglish

Related product manuals