1-5. Compressor frequency limitation by outdoor temperature
The minimum compressor frequency is limited by outdoor temperature as below.
Cooling/Dry mode
F zone
38°C
E zone
19°C
D zone
10°C
C zone
B zone
A zone
0°C
-10°C
Model name Outdoor temperature zone
Limitation of compressor
frequency
AOUG09LZAS1
AOUG12LZAS1
A zone 37 rps
B zone 37 rps
C zone 37 rps
D zone 28 rps
E zone 1 rps
F zone 22 rps
AOUG15LZAS1
A zone 33 rps
B zone 33 rps
C zone 33 rps
D zone 25 rps
E zone 10 rps
F zone 20 rps
1-5. Compressor frequency limitation by outdoor temperature - (04-5) - 1. Compressor frequency control