2-2. E: 11. Serial communication error (Serial forward transfer
error) (Indoor unit)
Indicator Indoor unit
Operation indicator 1 time flash
Timer indicator 1 time flash
Economy indicator Continuous flash
Error code E: 11
Detective actuator Indoor unit
Main PCB
When the outdoor unit cannot receive the serial signal
from indoor unit more than 10 seconds.
Fan motor
Forecast of cause
Connection failure
External cause
Main PCB failure
Indoor unit fan motor failure
Check point 1. Reset the power and operate
Does error indication show again?
→ If no, go to "Check point 1-2".
Check point 2. Check connection
Check any loose or removed connection line of indoor unit and outdoor unit.
Check connection condition is control unit. (If there is loose connector, open cable or mis-wiring.)
→ If there is an abnormal condition, correct it by referring to the installation manual or the “DESIGN
& TECHNICAL MANUAL”.
Check point 3. Check the voltage of power supply
Check the voltage of power supply
Check if AC 187 V (AC 208 V -10%) to AC 253 V (AC 230 V +10%) appears at
outdoor unit terminal L—N.
+
-
2-2. E: 11. Serial communication error (Serial forward transfer error) (Indoor unit) - (03-11) - 2. Troubleshooting with error code
TROUBLESHOOTING
TROUBLESHOOTING

Table of Contents

Other manuals for Fujitsu ASUG09LZAS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASUG09LZAS and is the answer not in the manual?

Fujitsu ASUG09LZAS Specifications

General IconGeneral
BrandFujitsu
ModelASUG09LZAS
CategoryAir Conditioner
LanguageEnglish

Related product manuals