SERVICE PARTS INFORMATION 2
Inverter Compressor
02-35
Check Point 1 : Check Connection
Check Point 2 : Check Winding Resistance
Check Point 3 : Replace Inverter PCB
C
S
R
Check terminal connection of Compressor
(loose or incorrect wiring)
Check winding resistance of each terminal
If the resistance value is 0 or infinite, replace Compressor.
If the symptom does not change with above Check 1, 2, replace Inverter PCB.
Resistance Value : 0.71
( at 20°C )
R
(RED)
S
(WHITE)
C
(BLACK)
Terminal cover opened