2. MODEL SELECTION
MODEL : AR
 
G18LLTA, AR
îš¾
G18LLTB
Outdoor Temperature
Indoor temperature (°CDB)
16.0 18.0 20.0 24.0 26.0
(°CDB) (°CWB) TC TC TC TC TC
-15.0 -16.0 4.74 4.31 3.93 3.53 3.04
-10.0 -11.0 5.30 4.83 4.40 3.95 3.41
-5.0 -7.0 5.90 5.37 4.89 4.39 3.79
0.0 -2.0 6.44 5.86 5.34 4.80 4.14
5.0 3.0 6.91 6.29 5.73 5.15 4.44
7.0 6.0 7. 07 6.43 5.86 5.27 4.54
10.0 8.0 7. 07 6.43 5.86 5.27 4.54
15.0 10.0 7.07 6.43 5.86 5.27 4.54
20.0 15.0 7.07 6.43 5.86 5.27 4.54
HEATING CAPACITY
TC : Total Capacity kW.
The data is based on the following conditions.
Pipe length : 5m [Outdoor unit - Branch box], 3m [Branch box - Indoor unit]
Height difference : 0m [Outdoor unit - Indoor unit].
- (02 - 31) -