4. INDOOR UNITS
ode nae AS
G07LMCA AS
G09LMCA AS
G12LMCA AS
G14LMCA
Power source    
aiabe otage range 
apacit . ass . ass . ass . ass
nput power W 15 17 22 28
unning current A 0.13 0.15 0.19 0.25
an
irow
rate
ooing
High
3
h
560 600 660 730
ed 500 520 560 600
ow 430 430 450 530
uiet 310 310 310 360
eating
High 560 600 660 730
ed 500 520 560 615
ow 430 430 470 560
uiet 330 330 330 375
pe  t rossow  
otor output W 30
ound pressure
ee 
ooing
High
d 
36 37 40 42
ed 32 33 36 38
ow 29 29 30 33
uiet 21 21 21 25
eating
High 36 37 40 42
ed 32 33 36 38
ow 29 29 31 35
uiet 22 22 22 27
ound power ee
ooing
High
db
51 52 54 56
eating 51 52 55 57
eat
echanger
iensions
    

ain     
ub     .
in pitch ain . ub .
ows  tages ain    ub   
Pipe tpe opper tube
in tpe uiniu
ncosure
ateria Postrene
oour
WHITE
 pproiate coour o  . 
iensions
    
et

    
ross     
eight
et
g
8.5
ross 10.5
onnection
pipe
ie
iuid

. in
as . in . in
ethod are
rain hose
ateria PPP
ie  . .. . to . ..
peration range
ooing
  to 
%RH  or ess
eating   to 
eote controer tpe ireess ired option
NOTE:
pecications are based on the oowing conditions.
Power source o specications  
ooing ndoor teperature o    and outdoor teperature o   .
eating ndoor teperature o    and outdoor teperature o   .
Pipe ength   utdoor unit  ranch bo   ranch bo  ndoor unit
eight dierence   utdoor unit  ndoor unit
he protectie unction a wor when using it outside the operation range.
 hese are the easured aues in the anuacturers anechoic chaber.
ecause o the surrounding sound enironent the sound ees easured in actua instaation conditions ight be higher than the
specied aues here.
    
INDOOR
UNITS
INDOOR
UNITS

Table of Contents

Other manuals for Fujitsu ASYG07LMCA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG07LMCA and is the answer not in the manual?

Fujitsu ASYG07LMCA Specifications

General IconGeneral
BrandFujitsu
ModelASYG07LMCA
CategoryAir Conditioner
LanguageEnglish

Related product manuals