2. TROUBLESHOOTING
02-01
2-1 ERROR DISPLAY
Please refer the flashing pattern as follows.
Indoor Unit : Model 07 / 09 / 12
The Operation, Timer and Economy lamps operate as follows according to the error contents.
Manual auto switch error
Room temp. sensor error
Indoor unit PCB model information error
Error Contents
Continuous
Continuous
4 times
Continuous2 times
3 times
3 times
5 times
Continuous1 times1 times
Trouble
shooting
(Green)
(Orange)
(Green)
1 times
Serial communication error
Indoor unit fan motor error
Indoor unit Heat Ex. middle temp.
sensor error
Continuous4 times 2 times
Continuous1 times5 times
Outdoor unit main PCB model
information error or communication error
Continuous
2 times6 times
Continuous
Continuous
4 times
7 times
6 times
1 times
Continuous
7 times 3 times
Continuous
7 times 4 times
Continuous
PFC circuit error
Discharge temp. sensor error
Outdoor unit Heat Ex. liquid temp.
sensor error
Outdoor temp. sensor error
1,2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Continuous
8 times
4 times
Current sensor error
Continuous
Continuous
Continuous
5 times9 times
Compressor rotor position detection error
4 times9 times
9 times 9 times
4-way valve error
1 times10 times
Discharge temp. error
Trip detection
Continuous
5 times6 times
Trip terminal L error
Indoor Unit Display
[ ]
[ ]
[ ]
Operation Timer
Economy
Outdoor unit fan motor error
Continuous
7 times9 times

Other manuals for Fujitsu ASYG09LLCE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG09LLCE and is the answer not in the manual?

Fujitsu ASYG09LLCE Specifications

General IconGeneral
TypeAir conditioner indoor unit
Multi-split-
Product colorWhite
Inverter technologyYes
Refrigerating mediumR410A
Air conditioner functionsCooling, Dehumidifying, Heating
Refrigerating medium weight650 g
Cooling capacity in watts (nominal)- W
Operating temperature (cooling) (T-T)-10 - 43 °C
Operating temperature (heating) (T-T)-15 - 24 °C
Heating capacity in watts (nominal) (Average heating season)3000 W
Airflow1670 m³/h
Outdoor unit noise level- dB
AC input voltage230 V
AC input frequency50 Hz
Design load (cooling)- kW
Annual energy consumption (cooling)127 kWh
Hourly energy consumption (cooling)- kWh
Indoor unit typeWall-mountable
Indoor unit depth206 mm
Indoor unit width820 mm
Indoor unit height262 mm
Indoor unit weight7000 g
Indoor unit noise level (high speed)720 dB