Trouble shooting 12
OUTDOOR UNIT Error Method:
Detective Actuators:
Detective details:
Forecast of Cause :
Check Point 2 :
6.19.812.516.120.827.2Resistance Value (k )
Temperature
OKOK
OKOK
3.9
0.60.81.21.82.6Resistance Value (k )
Temperature
Outdoor unit Heat Ex. liquid temp.
sensor error
Outdoor unit Main PCB
Heat exchanger temperature thermistor
When Heat exchanger temperature thermistor open or
short-circuit is detected at power ON or while running the compressor.
1. Connector connection failure 2.Thermistor failure 3. Main PCB failure
Check Point 1 : Check connection of Connector
Check if connector is removed.
Check erroneous connection.
Check if thermistor cable is open.
>>Upon correcting the removed connector or mis-wiring, reset the power.
Check Point 2 : Remove connector and check Thermistor resistance value
Thermistor Characteristics (Approx. value)
If Thermistor is either open or shorted, replace it and reset the power.
02-13
-5°C-10°C
87.2
-30°C
47.8
-20°C
80°C70°C60°C
30°C20°C10°C5°C0°C
50°C40°C
Indicate or Display:
Refer to error code table.
Check Point 3 :
Check Point 3 : Check voltage of Main PCB (DC5.0V)
Make sure circuit diagram of outdoor unit and check terminal voltage at Thermistor (DC5.0V)
If the voltage does not appear, replace Main PCB.
THERMISTOR
(PIPE)
THERMISTOR
(DISCHARGE)
THERMISTOR
(OUTDOOR)
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
1
2
3
4
1
2
3
4
1
2
3
1
2
3
CN71
CN70

Other manuals for Fujitsu ASYG09LLCE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG09LLCE and is the answer not in the manual?

Fujitsu ASYG09LLCE Specifications

General IconGeneral
TypeAir conditioner indoor unit
Multi-split-
Product colorWhite
Inverter technologyYes
Refrigerating mediumR410A
Air conditioner functionsCooling, Dehumidifying, Heating
Refrigerating medium weight650 g
Cooling capacity in watts (nominal)- W
Operating temperature (cooling) (T-T)-10 - 43 °C
Operating temperature (heating) (T-T)-15 - 24 °C
Heating capacity in watts (nominal) (Average heating season)3000 W
Airflow1670 m³/h
Outdoor unit noise level- dB
AC input voltage230 V
AC input frequency50 Hz
Design load (cooling)- kW
Annual energy consumption (cooling)127 kWh
Hourly energy consumption (cooling)- kWh
Indoor unit typeWall-mountable
Indoor unit depth206 mm
Indoor unit width820 mm
Indoor unit height262 mm
Indoor unit weight7000 g
Indoor unit noise level (high speed)720 dB

Related product manuals