02 - 16
)
-
OUTDOOR UNIT
AO
G09-14LT
OUTDOOR UNIT
AO
G09-14LT
ELECTRIC CHARACTERISTICS9.
Model name AO
G09LT AO
G12LT AO
G14LT
Power supply
Voltage V 230 ~
Frequency Hz 50
*1) Max operating current A 10.0 11.5 14.5
Starting Current A 3.3 4.3 6.1
*2) Wiring Spec.:
Main Fuse (Circuit breaker)
Current
A15 20
Power Cable mm
2
1.5 3.5-4.0
*3) Limited wiring length : m 15 13 24
*1) The maximum current is the total current of indoor unit and outdoor unit.
*2) Wiring Spec.:
Selected Sample
(Selected based on Japan Electrotechnical Standard and Codes Committee E0005)
*3) Limited wiring length :
This is the wiring length in case voltage descent is less than 2%.
When the wiring length becomes long, please select the wiring of a more larger diameter.