11. Safety devices
Type of
protection
Protection form
Model
AOYG09KMCBN AOYG12KMCBN AOYG14KMCBN
Circuit protection
Current fuse (Main PCB)
250 V, 25 A
250 V, 5 A
250 V, 3.15 A
Current fuse (Wire) 250 V, 3.15 A
Fan motor
protection
Thermal protection
program
Activate
100 ±15 °C
Fan motor stop
Reset
95 ±10 °C
Fan motor restart
Compressor
protection
Thermal protection
program
(Discharge temp.)
Activate
110 °C
Compressor stop
Reset
After 7 minutes
Compressor restart
Thermal protection
program
(Outdoor temp.)
(Only in COOL or DRY
mode)
Activate
-15 °C
Compressor stop
Reset
-10 °C
Compressor restart
- 48 -