1. Specifications
Type Inverter heat pump
Model name AOYG18KMTA AOYG24KMTA
Power supply 230 V ~ 50 Hz
Power supply intake Outdoor unit
Available voltage range 198—264 V
Starting current A 7.0 8.6
Fan
Airflow rate
Cooling
m
3
/h
2,350 3,240
Heating 2,100 2,820
Type × Q'ty Propeller fan × 1
Motor output W 49
Sound pressure level *1
Cooling
dB (A)
50 54
Heating 50 52
Sound power level
Cooling
dB (A)
65 67
Heating 65 66
Heat exchanger type
Dimensions
(H × W × D)
mm
Main1: 588 × 881 × 18.19
Main2: 588 × 851 × 18.19
Main1: 672 × 881 × 18.19
Main2: 672 × 851 × 18.19
Fin pitch 1.3
Rows × Stages 1 × 28 1 × 32
Pipe type Copper tube
Fin type
Type (Material) Aluminum
Surface treatment PC fin
Compressor
Type DC twin rotary
Motor output W 900 1,060
Refrigerant
Type (Global warming potential) R32 (675)
Charge g 1,020 1,320
Refrigerant oil
Type FW68S RmM68AF
Amount
cm
3
350 400
Enclosure
Material Steel sheet
Color
Beige
Approximate color of Munsell 10YR 7.5/1.0
Dimensions
(H × W × D)
Net
mm
632 × 799 × 290 716 × 820 × 315
Gross 692 × 940 × 375 776 × 961 × 450
Weight
Net
kg
36 42
Gross 40 46
Connection pipe
Size
Liquid
mm (in)
Ø6.35 (Ø1/4)
Gas Ø12.70 (Ø1/2)
Method Flare
Pre-charge length
m
15
Max. length 25 30
Max. height difference 20 25
Operation range
Cooling
°C
-10 to 46
Heating -15 to 24
Drain hose
Material PP
Size mm Ø13.0 (I.D.), Ø16.0 to Ø16.7 (O.D.)
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
– Pipe length: 5 m, Height difference: 0 m.
• Protective function might work when using it outside the operation range.
• *1: Sound pressure level
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
- 44 -
1. Specifications
OUTDOOR UNIT
AOYG18-24KMTA
OUTDOOR UNIT
AOYG18-24KMTA