SAFETY DEVICES2-10.
Protection form
Model
AO
A45L
Circuit protection
Current fuse (NEAR THE TERMINAL) 25A 250V
Current fuse (NEAR THE TERMINAL) 10A 250V
Current fuse (MAIN PRINTED CIRCUIT BOARD) 5A 250V
Current fuse (MAIN PRINTED CIRCUIT BOARD) 3.15A 250V
Fan motor protection Thermal protection program
OFF : 130±20°C
ON : 100±20°C
High Pressure Protection High Pressure Switch
OFF : 4.2±0.1MPa
ON : 3.2±0.15MPa
Compressor protection
Thermal protection program (COMPRESSOR TEMP.)
OFF : 110°C
ON : 80°C
Thermal protection program (DISCHARGE TEMP.)
OFF : 115°C
ON : After 7 minutes