Detailed technical specifications for various FUJITSU indoor unit types.
Detailed dimensional drawings and installation space requirements for indoor units.
Wiring diagrams for various FUJITSU indoor unit types.
Octave band sound pressure level curves for various indoor unit types and modes.
Electrical specifications: power supply, MCA, and wiring for indoor units.
Details on PCB fuses and fan motor thermal protectors for indoor units.
Specifications for FUJITSU outdoor units (AOYG72LRLA, AOYG90LRLA).
Dimensional drawings for FUJITSU outdoor units (AOYG72LRLA, AOYG90LRLA).
Guidelines for adequate installation space around the outdoor unit.
Refrigerant circuit diagrams for twin, triple, and double twin configurations.
Wiring diagrams for FUJITSU outdoor units.
Cooling and heating capacity tables for outdoor units under various conditions.
Compensation rates for pipe length and height difference for outdoor units.
Octave band sound pressure level curves for outdoor units.
Electrical specifications: power supply, MCA, MFA, and motor ratings.
Safety devices for outdoor units: fuses, thermal protectors, pressure switches.
General precautions for installing indoor and outdoor units.
Precautions for indoor unit installation, including prohibited locations.
Precautions for outdoor unit installation, including prohibited locations and wind/snow.
Guidelines for pipe material, thickness, lubricant, and tools for refrigerant piping.
Key considerations for R410A refrigerant, including pipe material and tools.
Allowable height difference, piping length, and pipe size limitations for correct operation.
Guidance on selecting pipe sizes for twin, triple, and double twin configurations.
Formulas and examples for calculating additional refrigerant charge based on piping.
Precautions and procedures for pipe installation, including brazing and bending.
Important warnings regarding piping material, brazing, and treatment.
Precautions for connecting pipes, including branch pipes and bending.
Precautions, power supply cable specs, wiring methods, and connection examples.
Safety warnings and regulations for electrical wiring connections.
Specifications for power supply cables, transmission cables, and bus wires.
Setting procedures for indoor unit parameters (address, function).
Overview, specifications, and installation of remote controllers.
Settings for DIP switch, jumper wires, and remote controllers.
Configuration of DIP switches and jumper wires for unit settings.
Procedure for setting functions using wireless remote controllers.
Procedure for setting functions using wired remote controllers.
Procedure for setting functions using simple remote controllers.
Location and functions of switch buttons on the outdoor unit control PCB.
Pre-test run checks, test operation methods, and error code tables.
Steps for performing test runs, including pre-test checks and operation modes.
Explanation of error display modes and error code table.
Steps for performing the pump down operation to recover refrigerant.