Precautions on air-outlet duct connection
Connect the air-outlet duct to maximum 2 directions among the 4-duct connecting directions.
CAUTION
Do not connect ducts at 3 or more directions.
A
B
C
D
When installing air-outlet duct in 2 directions, connect the ducts in a straight line.
Air-outlet duct
Air-outlet duct
CloseClose
Air-outlet duct
Air-outlet duct
Close
Close
Once the ducted direction is decided, be sure to close the outlet in the direction.
Use optional Air outlet shutter plate (UTR-YDZK) to close the outlet.
Duct (locally purchased)
Close the outlet here.
- 17 -
5-4. Duct connection
5. Fan performance
CASSETTE TYPE
AUXG18, 22KRLB
CASSETTE TYPE
AUXG18, 22KRLB