Turn off the scanner and wait for at least 15 minutes.
Disconnect the scanner from the power source.
Clear all documents from the ADF paper chute.
Open the Automatic Document Feeder cover.
Lift the roller and pull the shaft from the slot.
Detach the brake roller from its shaft.
Insert the protrusion of the new brake roller onto the shaft.
Insert the shaft into the designated holes to secure the roller.
Close the ADF cover and the Automatic Document Feeder.
Reconnect the power cable and power on the scanner.
Reset the counter via the Operator Panel or Software Operation Panel.
Turn off the scanner and wait for at least 15 minutes.
Disconnect the scanner from the power source.
Clear all documents from the ADF paper chute.
Open the Automatic Document Feeder.
Slide side guides and pull sheet guide open from the dip.
Rotate bushing and slide shaft to remove the roller.
Rotate bushing and pull shaft away from the scanner.
Lift retaining clip and pull pick rollers off the shaft.
Fit pick rollers onto the shaft, ensuring proper seating.
Insert the shaft into the scanner slot and secure the bushing.
Insert protrusion into hole, slide bushing, and fit to shaft.
Ensure both ends of the sheet guide are locked firmly.
Close the Automatic Document Feeder carefully.
Reconnect power and turn on the scanner.
Reset the counter via Operator Panel or Software Operation Panel.
Access the Software Operation Panel to view counter status.
Navigate to the Device Setting menu within the panel.
Review the listed consumable counters and their status.
Click the [Clear] button for replaced consumables or after cleaning.
Confirm the reset operation by clicking the [OK] button.
The settings are saved after confirmation.
Liquid cleaner for removing dirt and stains from the scanner.
Used to clean the inside of the scanner with Cleaner F1.
Pre-moistened wipes for cleaning scanner components.
Used for cleaning small parts like the ultrasonic sensor.
Used to wipe off dirt and stains, can be moistened with Cleaner F1.
Lists locations within the ADF requiring cleaning and frequency.
Lists locations on the flatbed requiring cleaning.
Notes on when cleaning must be performed more frequently.
Use dry cloth, cloth with Cleaner F1/mild detergent, or Cleaning Wipe.
Avoid solvents, moisture, and excessive cleaner.
Procedure for cleaning the ADF using Cleaning Paper and Cleaner F1.
Procedure for cleaning the ADF using a cloth moistened with Cleaner F1.
Open the scanner's document cover.
Clean document pad and bed with cloth/wipe and Cleaner F1.
Allow cleaned parts to dry, then gently close the document cover.