FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide
July 2019, Ver.2.0
Disk Unit for PCIe SFF (DU_PCIEA)
MC-5HDU61 / MCX5HDU61 (LD)
- Max. 2x Disk Units per Base Unit.
- 1x RAID Controller card per Disk Unit needs to be mounted.
- Max 4x PCIe-SSD SFFs can be mounted per Disk Unit.
SAS RAID Controller Card (EP540i)
MC-0JSR71 / MCX0JSR71 (LD)
- One RAID Controller card enables to mount
Max 4x PCIe-SSD SFFs
- 12Gbps for each disk drive. 4GB of cache memory
- RAID 0/1/1E/5/6/10 and hot spare supported
SAS RAID Controller Card (EP580i)
MC-0JSR81 / MCX0JSR81 (LD)
- One RAID Controller card enables to mount
Max 4x PCIe-SSD SFFs
- 12Gbps for each disk drive. 8GB of cache memory
- RAID 0/1/1E/5/6/10 and hot spare supported
- Connection between I/O Unit
and Disk Unit
I/O Unit #0 Disk Unit #0
I/O Unit #1 Disk Unit #1
Disk Unit for DMBU(Disk/MMB Unit) (DU_M)
8.Disk Unit
I/O Unit
Disk Unit
Disk Unit
-
Max. 2 of the following Disk Units can be mounted on the Base Unit.
- In order to mount Disk Unit #1, I/O Unit #1 is required.
PSU_M
#1
PSU_M
#0
I/O Unit
#1
I/O Unit #0
LAN
port
PCI Slots
x4
MMB #0
Disk
Unit_M
#1
PSU#3
PSU#2PSU#1
PSU#0
MMB #1
Disk Unit #0
HDD/SSD
RAID
Card
FBU
SB #0
Memory
x12 slots
CPU
Memory
x12 slots
CPU
SB #1
Disk Unit #1
Disk Unit_M #0
HDD/SSD
RAID
Card
FBU
Disk
Unit_M
#2
Disk
Unit_M
#3
I/O Unit
#2
I/O Unit
#3
SB #2
SB #3
18 of 42