Line Function Setting range or display Setting
increment
Basic setting
850 Floor curing function (gure 15)
- Off : Early interruption of the current programme, programme inactive
- Functional heating
- Curing heating
- Functional heating + curing heating
- Curing heating + functional heating
- Manually
Manual mode enables you to programme your own concrete slab drying time.The function ends automatically after
25 days.
851 Floor curing setp manually
(if line 850 = manual)
0... 95 °C 1 °C
This function enables you to set the custom concrete slab drying temperature. This temperature remains xed.
The concrete slab-drying programme stops automatically after running for 25 days.
856 Floor curing day current 0... 32
857 Days complete.current 0... 32
900 Operating mode changeover None, Protection mode,
Reduced, Comfort, Automatic
1
Operating mode at end of concrete slab drying period
"
50
45
40
35
30
20
50
25
55
1 15 7
X
10
18
25
15
1
gure 15 - Diagram of the concrete slab drying programmes
Heating ow temperature °C
Functional heating + Curing heating
Curing heating
Day
Functional
heating
Installation and operating manual "1395 - EN" - 19 -