En-10
When you return to the “Monitor” screen, the icon is displayed.
To check the function, press the [Enter button] and select the
icon.
Cool
Monitor
High
°
C
24
Menu
Set temp. auto return: Remaining 30 minutes
Mo
10:00
End:
3-2-4. Set temp. range limitation setting
1
In “Function” screen, select [Set temp. range] with the
[Cursor button (Up/Down)].
Function
Air flow direction
Economy
Set temp. auto return
Set temp. range
Off
Disable
Timer
Mo
10:00
Disable
Setting:
Back:
To change the setting, press the [Enter button].
2
“Set temp. range” screen is displayed.
Set temp. range
Enable/Disable setting
Temp. setting
Cool/Dry
Heat
Auto
Lower
Upper
18
°
C
30
°
C
30
°
C
30
°
C
16
°
C
18
°
C
Disable
Mo
10:00
Setting:
Back:
Set temp. au...
Air flow dire...
Select the item with the [Cursor button (Up/Down)], and
press the [Enter button].
3
For [Enable/Disable setting], select [Enable] or [Disable]
with the [Cursor button (Up/Down)], and press the [Enter
button] to complete the setting.
Enable/Disable setting
Enable
Set temp. range
Temp. setting
Cool/Dry
Heat
Auto
Lower
Upper
18
°
C
30
°
C
30
°
C
30
°
C
16
°
C
18
°
C
Mo
10:00
OK:
Cancel:
Set temp. au...
Air flow dire...
4
For [Temp. setting], select mode with the [Cursor but-
ton (Up/Down)] and press the [Enter button].
Adjust [Lower] and [Upper] value with the [Cursor but-
ton (Up/Down)].
With the [Cursor button (Left/Right)], the cursor can be
switched [Lower] and [Upper].
To complete the setting, press the [Enter button].
Set temp. range
Enable/Disable setting
Temp. setting
Cool/Dry
Heat
Auto
Lower
Upper
18
°
C
30
°
C
30
°
C
30
°
C
16
°
C
18
°
C
Enable
Mo
10:00
Set temp. au...
Air flow dire...
OK:
Cancel:
Notes
Possible temperature setting ranges in the operation
mode are as follows:
Cool, Dry, Auto ................ 18 to 30 °C (64 to 88 °F)
Heat ................................. 16 to 30 °C (60 to 88 °F)
If the temperature out of the Set temp. range limitation
is set, it will be reset at the nearest temperature within
the range.
Even if the temperature setting change is done on the
secondary remote controller, it returns to temperature
within the range set in [Set temp. range] on the
primary remote controller.
When you return to the “Monitor” screen, the icon is displayed.
To check the function, press the [Enter button] and select the
icon.
Menu
Cool
Monitor
Mo
10:00
High
°
C
26
Set temp. range
End
:
9380221043_OM.indb 10 8/22/2012 3:54:58 PM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu UTY-RVN*M and is the answer not in the manual?

Fujitsu UTY-RVN*M Specifications

General IconGeneral
BrandFujitsu
ModelUTY-RVN*M
CategoryController
LanguageEnglish

Related product manuals