5. Position the signal cable so that no more than 4 cm of the sheath is exposed as shown
in the figure below. Tighten fixing bolts.
Sheath
CABLE GLAND
Plate
Gasket
Flat
washer
Bolt
Within 4 cm
Tubing
Shield
How to fix signal cable in cable gland
6. Unfasten four screws shown in the figure below.
Four screws
Antenna unit chassis, cover opened
7. Pass the signal cable through the cable protector.
Cable
protector
Antenna unit chassis, cover opened