Questions and Answers

  • J
    joshuabergerSep 23, 2025
    How to fix Furuno FAR-1528-BB showing only two PI lines?
    • S
      Stephanie SmithSep 23, 2025
      If your Furuno Marine Radar is only showing two PI lines when six are desired, it is likely due to an incorrect setting of the PI line interval or an inappropriate setting for the number of PI lines to display. Adjust the PI line interval. Also, check the menu setting for the number of PI lines.
  • B
    Brianna GrahamAug 23, 2025
    Why Furuno FAR-1528-BB cannot turn on?
    • M
      Miranda FergusonAug 25, 2025
      If your Furuno Marine Radar cannot be turned on, the cause may be a blown fuse, incorrect mains voltage/polarity, or a faulty power supply board. To resolve this, replace the blown fuse, correct the wiring and input voltage, or replace the power supply board.
  • M
    msanchezAug 25, 2025
    What to do if Furuno FAR-1528-BB Marine Radar picture not updated?
    • K
      Kathleen LopezAug 25, 2025
      If the picture on your Furuno Marine Radar is not updating or is frozen, this is likely due to a video freeze. Turn the power off and on again to restore normal operation.
  • R
    Robert DavisAug 26, 2025
    Why Furuno FAR-1528-BB shows marks and noise but no echo?
    • B
      Brian JohnstonAug 27, 2025
      If you see marks, indications, and noise but no echo on your Furuno Marine Radar, the Tx high voltage protection circuit may have been activated. Reset the power to restore normal operation.
  • D
    David BrownAug 27, 2025
    How to fix Furuno FAR-1528-BB Marine Radar when range changed but picture not changing?
    • T
      Teresa GibsonAug 27, 2025
      If the range is changed on the Furuno Marine Radar but the picture is not changing, it could be due to a defective range key, a faulty SPU board, or a video freeze-up. Try adjusting the range with the control unit or the [RANGE] box several times; if that doesn't work, the keypad may need replacement. If still not working, replace the SPU board. Alternatively, try turning the radar off and on.
  • J
    Jessica RamirezSep 16, 2025
    Why Furuno FAR-1528-BB Marine Radar interference rejector is inoperative?
    • N
      nicholslisaSep 16, 2025
      If the interference rejector on your Furuno Marine Radar is inoperative and the interference rejection level is not displayed, the issue is likely with the SPU board. Replace the SPU board.
  • M
    Maxwell WestSep 13, 2025
    How to fix Furuno Marine Radar target not tracked correctly?
    • J
      John SantosSep 13, 2025
      If a target is not being tracked correctly on your Furuno Marine Radar, it may be due to poor definition of targets in sea clutter. Adjust A/C SEA and A/C RAIN.
  • S
    Steve FloresSep 14, 2025
    Why cannot operate Furuno FAR-1528-BB from on-screen boxes?
    • T
      Trevor StevensonSep 15, 2025
      If you cannot operate the radar from the on-screen boxes on your Furuno Marine Radar, the issue is likely with the SPU board. Replace the SPU board.
  • C
    Christy AcostaSep 5, 2025
    Why Furuno FAR-1528-BB Marine Radar shows marks but no noise when GAIN adjusted?
    • A
      Amanda CollinsSep 6, 2025
      If, with the GAIN adjusted and A/C SEA set to minimum, marks and indications appear on your Furuno Marine Radar but there is no noise or echo, it could be due to the IF amplifier, the signal cable between the antenna and processor unit, or the video amplifier board. Replace the IF amplifier. Check the continuity and isolation of the coaxial cable (disconnect the plug and lugs at both ends before checking with an ohmmeter). Check the video coax line for a secure connection; if the connection is good, replace the SPU board.
  • B
    Brian HaleySep 3, 2025
    Why Furuno FAR-1528-BB Marine Radar picture is not updated with each sweep?
    • R
      Ryan MillsSep 3, 2025
      If the picture on your Furuno Marine Radar is not updating with each sweep, it could be due to slots in the rotating disc in the antenna unit or the motor brushes. Remove any foreign material (carbon, grease, etc.) from the slots. If the motor brushes are shorter than 6 - 7 mm, replace them.

Summary

IMPORTANT NOTICES

General

Covers manual usage guidelines, copyright, warranty, and safety advice for proper operation.

How to discard this product

Instructions for proper disposal of the equipment according to local regulations.

SAFETY INSTRUCTIONS

Radio Frequency Radiation Hazard

Warns about harmful RF energy emitted by the radar antenna, advising safe distances and eye protection.

FOREWORD

Features

Highlights key capabilities like trackball operation, integrated functions (TT, AIS), and alarm systems.

1. OPERATIONAL OVERVIEW

1.1 Controls

Details the functions and operation of the RCU-028 control unit for the radar system.

1.5 Menu Operations

Explains how to navigate and operate the radar's main menu system for various functions.

1.14 User Settings

Describes how to reset, store, and load user-specific settings for radar operation.

2. RADAR OBSERVATION

2.2 False Echoes

Explains the causes and types of false echoes like multiple echoes and sidelobes.

3. TARGET TRACKING (TT)

3.1 Precautions for Target Tracking Usage

Provides essential warnings and precautions for effective and safe use of target tracking features.

3.14 Collision Alarm (CPA, TCPA)

Describes how to set CPA and TCPA ranges for collision avoidance alarms.

4. AIS OPERATION

4.1 Controls for AIS

Details the control functions for operating the Automatic Identification System (AIS) on the radar.

5. VIDEO PLOTTER OPERATION

5.2 Radar Map

Explains how to create, display, and manage radar maps with various map symbols.

6. MAINTENANCE, TROUBLESHOOTING

6.1 Periodic Maintenance Schedule

Outlines regular checks and maintenance tasks for optimal performance and equipment longevity.

6.5 Easy Troubleshooting

Offers step-by-step procedures for users to resolve common operational issues.

Furuno FAR-1528-BB Specifications

General IconGeneral
BrandFuruno
ModelFAR-1528-BB
CategoryMarine Radar
LanguageEnglish

Related product manuals