EasyManua.ls Logo

Furuno FAR-2238S-NXT-BB - Power Supply Requirements; Environmental Conditions

Furuno FAR-2238S-NXT-BB
332 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FURUNO
FAR-2xx8 SERIES
SP - 4 E3652S01T-M
240130
5.3 Ethernet interface for IEC61162-450
Port (LAN2) 100Base-TX, IPv4, 8P8C connector
Data sentences Same as 5.2 sentences
IEC61162-450 transmission group
Input MISC, TGTD, SATD, NAVD, TIME, PROP, CAM1, CAM2, NETA
Output ALC, ALF, ALR, HBT sentence: TGTD, BAM1, BAM2
(default: TGTD)
other sentences: MISC, TGTD, SATD, NAVD, VDRD, RCOM,
TIME, PROP, USER1 to USER8 (default: TGTD)
Multicast address 239.192.0.1 to 239.192.0.18, 239.192.0.56
Destination port 60001 to 60018, 60056
Re-transmittable binary image transfer
Multicast address 239.192.0.26 to 239.192.0.30
Destination port 60026 to 60030
Other network function excepted IEC61162-450
SNMP, HTTP, Syslog, Furuno Management Protocol (FMP)
5.4 Output port on antenna unit
Sub display (for radar) 1 port: HD, BP, Trigger and Video signal
6 POWER SUPPLY
6.1 Processor unit (w/ antenna and transceiver unit)
FAR-2218/2318 100-230 VAC: 2.1-1.0 A (2.9-1.3 A), 1 phase, 50-60 Hz or
24 VDC (21.6-31.2V): 5.4 A (9.0 A)
FAR-2228/2328 100-230 VAC: 2.3-1.1 A (3.2-1.4 A), 1 phase, 50-60 Hz or
24 VDC (21.6-31.2V): 8.9 A (12.4 A)
FAR-2228-NXT/2328-NXT 100-230 VAC: 2.1-1.1 A (2.9-1.3 A), 1 phase, 50-60 Hz or
24 VDC (21.6-31.2V): 8.2 A (11.1 A)
FAR-2328W 100-230 VAC: 2.3-1.1 A (3.2-1.4 A), 1 phase, 50-60 Hz
FAR-2238S/2338S/2338SW 100-230 VAC: 3.2-1.5 A (5.6-2.5 A), 1 phase, 50-60 Hz
FAR-2238S-NXT/2338S-NXT 100-230 VAC: 2.6-1.2 A (5.1-2.2 A), 1 phase, 50-60 Hz
( A): 42 rpm
6.2 Monitor unit
MU-190 100-230 VAC: 0.5-0.4 A, 1 phase, 50-60 Hz
MU-190HD 12-24 VDC (10.8-31.2V): 8.4-3.9 A
MU-231 100-230 VAC: 0.7-0.4 A, 1 phase, 50-60 Hz
MU-270W 100-230 VAC: 0.6-0.4 A, 1 phase, 50-60 Hz
HD19T22-FUD-MA1/MA4-FAGA (option, standard supply for FAR-22x8 HK configuration)
100-240 VAC: 0.8-0.3 A, 1 phase, 50/60 Hz or 24 VDC: 3.1 A
6.3 HUB (option) 100-230 VAC: 0.1 A max. 1 phase, 50/60 Hz
6.4 De-icer (option) 100-115/220-230 VAC: 2.6/1.3 A, 1 phase, 50-60 Hz
7 ENVIRONMENTAL CONDITIONS
7.1 Ambient temperature
Antenna unit -25°C to +55°C (storage: -25°C to +70°C)
Indoor units -15°C to +55°C (storage: -20°C to +70°C)
7.2 Relative humidity 93% or less at +40°C
7.3 Degree of protection
Antenna unit IP56

Table of Contents

Other manuals for Furuno FAR-2238S-NXT-BB

Related product manuals