MARINE RADAR
FAR/FR-2805 Series
Radar ARPA Bacic Spec.
( ) FR-2815
( ) FR-2825
( ) FR-2855
( ) FR-2825W
( ) FR-2855W
( ) FR-2835S
( ) FR-2835SW
( ) FR-2865SW
( ) FAR-2815
( ) FAR-2825
( ) FAR-2855
( ) FAR-2825W
( ) FAR-2855W
( ) FAR-2835S
( ) FAR-2835SW
( ) FAR-2865SW
( ) FA-2805
X-band, 12 kW, TR up
X-band, 25 kW, TR up
X-band, 50 kW, TR up
X-band, 25 kW, TR down
X-band, 50 kW, TR down
S-band, 30 kW, TR up
S-band, 30 kW, TR down
S-band, 60 kW, TR down
Add-on ARPA

Table of Contents

Questions and Answers

  • A
    Ashley RodriguezAug 18, 2025
    Why is my Furuno FAR-2805 picture not updating?
    • G
      gbrownAug 19, 2025
      If the Furuno Marine Radar picture isn't updating, consider the following: 1. Check the signal cable connection. 2. Replace the SPU Board. 3. Turn the radar off and on.
  • E
    eric42Aug 21, 2025
    How to fix Furuno Marine Radar antenna not rotating?
    • S
      Samuel JonesAug 21, 2025
      If the Furuno Marine Radar antenna is not rotating, check these items: 1. Ensure there's no short circuit across #1 and #2 of J461 on the INT-9170 Board. 2. Press the relay reset button. 3. Confirm that the antenna switch is on.
  • A
    anna73Aug 23, 2025
    Why is Furuno Marine Radar sensitivity poor after adjusting TUNE control?
    • E
      Edward LeeAug 23, 2025
      If adjusting the TUNE control on your Furuno Marine Radar results in poor sensitivity, consider these potential causes: 1. The magnetron may be deteriorated; with radar transmitting on 48 mm range, check magnetron current and replace the magnetron if the current is below normal. 2. The MIC may be detuned; check MIC detecting current and tune the MIC if it's below normal. 3. There may be dirt on the radiator face; clean the radiator surface. 4. There may be water in the wave-guide or other feeder line; remove the water. 5. Second trace rejection may be ON; disable the second-trace rejector.
  • A
    Andrea SheltonAug 26, 2025
    How to fix Furuno FAR-2805 CRT brilliance adjusted but no picture?
    • W
      William HernandezAug 26, 2025
      If the CRT brilliance is adjusted but there is no picture on the Furuno Marine Radar, check these: 1. If it is a single display installation without radar inter-switching, make sure RADAR 1 is selected on the SYSTEM SETTING menu. 2. Check the high voltage supply with utmost care. 3. Replace the SPU Board.
  • L
    lindseykimberlyAug 28, 2025
    Why Furuno Marine Radar range changed but radar picture does not change?
    • A
      Anne OrtizAug 28, 2025
      If the Furuno Marine Radar range is changed but the radar picture does not change, try the following: 1. Hit the [+] and [-] RANGE keys several times; if this doesn't work, the keypad may need replacement. 2. Replace the SPU Board. 3. Replace the Mother Board. 4. Turn the radar off and on.
  • J
    Jessica GreeneAug 30, 2025
    What causes Furuno FAR-2805 Marine Radar true motion to not work correctly?
    • D
      David LoganAug 30, 2025
      If true motion presentation is not working correctly on your Furuno Marine Radar, here are some things to check: 1. Try pressing the MODE key a little harder. 2. Press the MODE key until 'TM' appears. 3. Enter the correct own ship speed. 4. Make sure that speed and compass inputs are accurate.
  • S
    Susan ReynoldsSep 1, 2025
    Why is Furuno Marine Radar picture orientation incorrect?
    • D
      david49Sep 2, 2025
      If the Furuno Marine Radar picture has incorrect orientation, note that the message 'HD SIG MISSING' appears when the heading pulse is not received during stand-by. Replace the gyro interface.
  • B
    Brandon RogersSep 4, 2025
    What to do if Furuno FAR-2805 Marine Radar interference rejector is inoperable?
    • K
      Kristen JordanSep 4, 2025
      If the interference rejector is inoperable on your Furuno Marine Radar (interference rejection level not displayed), check these: 1. Repair the contact of the key. 2. Replace the SPU Board. 3. Replace the Mother Board.
  • H
    Hannah HancockSep 6, 2025
    Why is Furuno FAR-2805 echo stretch ineffective?
    • R
      rmunozSep 6, 2025
      If the echo stretch is ineffective on your Furuno Marine Radar (Neither "ES1" nor "ES2" is displayed), check the following: 1. Repair the contact of the key. 2. Replace the SPU Board.
  • D
    Dylan HughesSep 8, 2025
    How to fix Furuno Marine Radar target not tracked correctly?
    • J
      jeffreycamachoSep 8, 2025
      If targets are not tracked correctly on your Furuno Marine Radar, adjust the A/C SEA and A/C RAIN controls.

Summary

SAFETY INSTRUCTIONS

DANGER

Critical warnings regarding severe hazards like electrical shock.

WARNING

Safety precautions for RF radiation and electrical hazards.

WARNING

Additional safety warnings for equipment operation and handling.

1. OPERATION

1.1 Turning on the Power

Step-by-step guide to powering on the radar unit.

1.2 Transmitter ON

How to activate the radar transmitter from standby mode.

1.3 Controls

Overview of the main control panel and its functions.

1.13 Suppressing Sea Clutter

Using controls to reduce sea clutter interference.

1.14 Suppressing Precipitation Clutter

Methods to reduce clutter from rain, snow, or clouds.

1.16 Measuring the Range

Using VRMs to accurately measure target range.

1.17 Measuring the Bearing

Using EBLs to determine target bearing.

1.18 Collision Assessment by Offset EBL

Using EBLs to assess collision risk and target course.

1.20 Setting a Guard Zone (Guard Alarm)

Configuring an alarm zone to detect approaching targets.

1.24 Electronic Plotting Aid (EPA)

Manually plotting targets to assess motion trends.

1.41 Alarms

Overview of visual and audible alarms for system events.

2. OPERATION OF ARPA

2.3 ARPA Menu Operation

How to navigate and set ARPA parameters via menus.

2.4 Start-up Procedure

Steps to activate and configure the ARPA system.

2.12 Setting CPA;TCPA Alarm Ranges

Setting limits for collision avoidance alarms.

2.13 Setting a Guard Zone

Activating and configuring guard zones for alarms.

2.14 Operational Warnings

Explains ARPA alarms for various situations.

2.15 Trial Maneuver

Simulating ship maneuvers to predict target reactions.

2.17 Criteria for Selecting Targets for Tracking

How ARPA selects and tracks targets based on criteria.

3. RADAR OBSERVATION

5. TROUBLESHOOTING

5.1 Easy Troubleshooting

User-level troubleshooting for common radar problems.

5.2 Advanced-level Troubleshooting

Hardware and software issues requiring qualified service personnel.

5.3 Diagnostic Test

Program for testing major circuit boards in the radar unit.

Furuno FAR-2805 Series Specifications

General IconGeneral
Display TypeLCD
Output Power25 kW
TypeMarine Radar
Frequency9.4 GHz (X-band)
RangeUp to 96 nautical miles
Rotation Speed24 rpm (standard), 48 rpm (optional)