EasyManua.ls Logo

Furuno FM-8800D - Distress Alert Transmission with Nature of Distress

Furuno FM-8800D
137 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2. DSC DISTRESS COMMUNICATION
2-4
2.2 Distress Alert Transmission with Nature of
Distress
If you want to transmit the distress alert with nature of distress specified, do as
follows:
1. Open the DISTRESS key cover and press the DISTRESS key momentarily.
The alarm sounds and the red lamp in the key blinks and after releasing the key
within four seconds the alarm stops and the red lamp goes off. The following
screen appears.
** Compose Message **
NATURE : UNDESIGNATED
POS:12
°
34N 123
°
45E
AT:12:34
SIMP TP
CALL TYPE : DISTRESS
UNDESIGNATED
Fire
Flooding
Collision
Grounding
Listing
G
2. Rotate the channel knob to choose the nature of distress. On the remote
handset, press the up or down arrow key.






F

 


 ! 
G
3. Press the ENT key. The screen changes as follows.
** Compose Message **
CALL TYPE : DISTRESS
NATURE : Flooding
AT : 08 : 00
POS :
34° 41. 1234’ N
134° 30. 4321’ E
TELEPHONE
ACK REQ
The own ship's position and current time in UTC are displayed if your
FM-8800D/8800S is connected to a navigation equipment, for example, GPS.