4. INCORPORATION OF DGPS BEACON RECEIVER KIT (for GP-1850W)
18
Handling of Coaxial Cable
Do not touch the connector with bare hands;
use gloves.
Use radio pincers to remove, and pull out
straightly.
Plug in connector straightly.
3. Fasten the GR-7000A (DGPS beacon receiver) to the heat sink with four 3X8 screws as
shown in the figure below.
Screws (3 X 8), 4pcs.
DGPS beacon receiver
GR-7000A
GN-8091
Installation of DGPS beacon receiver
4. Open the cover of GR-7000A to connect two coaxial cables shown below.
J2
From GN-8091
J3
J1
Piece of shrink tubing
Cable assy.
S.FL2-2LP0.7-D-WHT (250) (Supplied with DGPS kit)
Mini pin coax. cable
Connecting the coaxial cables in GR-7000A