25
Optional transducer
The optional Distributor MB-1000 is required to connect the optional transducers 50B-6, 50B-6G,
200B-5S, 200B-5S, 50/200-IT. The optional cable assy 02S4089 (Code No. 000-133-622, 1 m) is
required to connect the Distributor.
Distributor MB-1000, cover removed
Fabricating the transducer cable
Fabricate the transducer cable as below and connect it to the Distributor, referring to the intercon-
nection diagram.
How to fabricate the transducer cable
Distributor MB-1000 (Code No.: 000-040-809)
Part Type Code No. Qty Remarks
Distributor MB-1000 000-040-805 1
Crimp-on Lug FV1.25-3, red 000-538-113 6
Cord Lock NC-1 000-516-650 1 Used to connect two transducers
Connect 8P connector to
cable assy. 02S4089.
Shield
Transducer
50B-6/6G
200B-5/5S
50kHz
200kHz
SHIELD
R/W*
R/W*
BLK
BLK
TB2
1
2
3
4
5
J2 J1
WHT
3
2
1
BLK
TB1
02P6168
Detach grommet;
attach cord lock.
* R/W = Red/White
Crimp-on Lug
FV1.25-3, Red
Clamp here.
Taping
Vinyl Sheath
Shrink Tubing
Shield