29
Output
1) Rotate the [ENTER] knob to choose appropriate option and then push the [ENTER] knob.
2) Rotate the [ENTER] knob to choose Off or On as appropriate and then push the [ENTER]
knob followed by W.
6. Repeat step 5 to set up other ports.
7. Press the [MENU] key to close all open windows and erase the menu bar.
I/O format
Input data, sentence priority
Port I/O format Data sentence Remarks
Input NMEA 1, NMEA 2 IEC-61162-1,
NMEA-0183
Ver. 1.5/2.0/3.0
See table below.
PC/NMEA IN RS232, and IEC
and NMEA above
For NMEA IN, see
table below.
Output NMEA 1, NMEA 2 IEC-61162-1,
NMEA-0183
Ver. 1.5/2.0/3.0
GLL, VTG, BWR, DBT,
DPT, MTW, VHW,
WCV, APA, APB,
HDG, BOD, XTE,
RMA, RMB, RMC,
GGA, HSC, WPL,
RTE, TLL OUT, AAM,
GTD, MWV, ZDA
BWR: Rhumb line
PC/NMEA IN RS232
Data Sentence priority order Remarks
Speed thru water VHW
True heading HDT, HDG, HDM
Magnetic heading HDT, HDG, HDM
Target position TLL
Radiotelephone target position DSC, DSE
Waypoint data RMB
Depth DPT, DBT
Water temperature MTW
Wind current, speed MWV
Off
On