7. FISH FINDER (SOUNDER)
7-14
7.12.2 Fish size correction
The fish size shown on the screen can be different from the true size. If the size is
wrong, add an offset to the measured value to get a more accurate indication on the
screen.
1. Open the home screen, then tap [Settings] - [Sounder].
2. Drag the slider at [ACCU-FISH Size Correction] to set correction percentage (set-
ting range: -80% to 100%).
3. Tap the close button to finish.
7.12.3 How to turn the fish symbol indication on or off
Tap the screen to open the pop-up menu. Turn [ACCU-FISH] on or off. Fish symbols
and their depth values or fish lengths appear on the screen. If you selected [Off] at
step 5 in paragraph 7.12.1, the fish symbols are hidden and only the depth values or
fish lengths appear.
7.12.4 How to display the fish information
Tap a fish symbol to display the information (size, depth, bearing and range) about the
fish.
7.12.5 How to set the minimum size of ACCU-FISH
symbols
If you are in an area where there are many fish, the screen may become congested
with ACCU-FISH
symbols. To prevent this, you can set the minimum size for the
symbols. Open the [Sounder] menu. Tap [ACCU-FISH Minimum Size] to show the
software keyboard. Enter the minimum size (0 to 79.98 (inch)) then tap . Tap the
close button (x) to finish.
Setting Revised size
+100 Two times
+0 1.5 times
-50 1/2
-65 1/3
-75 1/4
-80 1/5

Table of Contents